Building regulations for roof insulation

Roof insulation thickness for building regulations will vary depending on the type of insulation used. Used within a Bauder waterproofing system our products meet current UK Building Regulations Part B for fire protection.

Different insulants have different efficiencies and performance levels which affects the thickness required to meet building regulations. This table shows a comparison of the insulations when looking to achieve different U-values on a plywood deck.

Warm roof insulations


0.11W/m²K on a plywood deck0.13W/m²K on a plywood deck0.18W/m²K on a plywood deck
Insulation TypeThickness
(mm)
Approx Weight Loading
(kg/m²)
Thickness
(mm)
Approx Weight Loading
(kg/m²)
Thickness
(mm)
Approx Weight Loading
(kg/m²)
BauderPIR FA-TE20061604.81203.6
BauderPIR FA20061604.81203.6
BauderPIR FA G16 (average thickness)20061604.81203.6
BauderVIP TE*11017.980176013
BauderROCK33553.629046.420032
BauderGLAS310312602619019

*U-value based upon ratio of 80% BauderVIP TE in combination with 20% BauderPIR FA-TE with an additional 30mm layer of BauderPIR FA-TE for 0.11W/m²K.

Inverted roof insulations

Key:
*1 layer
** 2 layers
*** 3 layers
BauderGLAS Inverted includes a base layer of BauderGLAS T3+

Excluding correction in BS6229:2018 - 4.6.2.2 Inverted Roofs


0.11W/m2K on a 150 mm concrete deck with a lambda value of 2.500 W/mK0.13 W/m2K on a concrete deck with a lambda value of 2.500 W/mK0.18 W/m2K on a concrete deck with a lambda value of 2.500 W/mK
Insulation TypeThickness
(mm)
Approx Weight Loading
(kg/m²)
Thickness
(mm)
Approx Weight Loading
(kg/m²)
Thickness
(mm)
Approx Weight Loading
(kg/m²)
BauderJFRI PREMIUM+ Hard Landscape265**7.95225**6.75165*4.95
BauderJFRI PREMIUM+ Soft Landscape280**8.40240*7.20175*5.25
BauderJFRI PREMIUM 300 Hard Landscape280**11.20240*9.60175*7.00
BauderJFRI PREMIUM 300 Soft Landscape300**12.00255**10.20185*7.40
BauderXPS 300310***9.30260***7.80190**5.70
BauderGLAS Inverted360**36.00300**30.00220**22.00

Including correction in BS6229:2018 - 4.6.2.2 Inverted Roofs


0.11W/m2K on a concrete deck with a lambda value of 2.500 W/mK0.13 W/m2K on a concrete deck with a lambda value of 2.500 W/mK0.18 W/m2K on a concrete deck with a lambda value of 2.500 W/mK
Insulation TypeThickness
(mm)
Approx Weight Loading
(kg/m²)
Thickness
(mm)
Approx Weight Loading
(kg/m²)
Thickness
(mm)
Approx Weight Loading
(kg/m²)
BauderJFRI PREMIUM+ Hard Landscape290**8.70250**7.50180*5.40
BauderJFRI PREMIUM+ Soft Landscape310**9.30265**7.95190*5.70
BauderJFRI PREMIUM 300 Hard Landscape310**12.40265**10.60190*7.60
BauderJFRI PREMIUM 300 Soft Landscape330**13.20280**11.20200*8.00
BauderXPS 300340***10.20290***8.70210**6.30
BauderGLAS Invertedn/an/a320**32.00230**23.00

England and Wales - Part L of Building Regulations - Conservation of fuel and power

Separate criteria are set out in approved documents; L1 is specific to dwellings and L2 relates to buildings other than dwellings. These are then split into four sections and for new construction are based on notional buildings:

  • L1A New Dwellings - 0.13 W/m²K
  • L1B Existing Dwellings - 0.18 W/m²K
  • L2A New Buildings other than Dwellings - 0.18 W/m²K
  • L2B Existing Buildings other than Dwellings - 0.18 W/m²K

More via Government Planning Portal ►

Scotland - Section 6 of the Scottish Building Regulations - Energy

Revised target levels for roofs are to be implemented from October 2015 and are approaching or exceeding the Passivhaus standard for buildings:

  • Domestic buildings - 0.11 W/m²K
  • Non Domestic buildings - 0.18 W/m²K for heated and naturally vented notional buildings
  • Non Domestic buildings - 0.16 W/m²K for heated and mechanically vented notional buildings

More via The Scottish Government ►