Bauder Total Roof System

When to specify...

Bauder Total Roof System is suitable for a variety of applications on both new build and refurbishment projects and can be used in warm, cold and inverted roof scenarios. There is also the option of using a root resistant cap sheet, making this waterproofing system ideal for green roof situations.  BBA certification is granted for the entire system and for when it incorporates our Plant E cap sheet for root resistant green roof waterproofing.

    Product Data

BTRS self adhered system

1 Bauder K5K cap sheet download K5K product datasheet pdf Download the product DoP
2 BauderTEC KSA DUO underlayer download product datasheet pdfDownload the product DoP
3 PIR FA-TE Insulation
or
PIR Tapered (laid to falls)
download product datasheet for PIR FA-TEDownload the product DoP for PIR FA-TE
4 BauderTHERM DS1 DUO download product datasheet pdfDownload the product DoP
 
  • Key features
      Capping sheets with tensile strength up to 1000N/50mm
      Withstands climatic extremes of over 100C variation
      Patented self-adhesive DUO products
      Expandable graphite fire retardant prevents spread of flame
  • Benefits
      Heavy duty, robust and extremely tough
      Service life in excess of 40 years as stated in BBA Certificate 10/4744
      Resistant to European climatic conditions
      Membrane resists impact and tearing
      Satisfies requirements of Part B of Building Regulations
  • Approvals, certification and guarantee
      Comprehensive range of guarantees with high level value of cover
      BBA Certificate 10/4744 for Bauder Total Roof System and Bauder Total
       Green Roof System

      BS EN 13707 - Reinforced Bitumen Membrane Sheets Compliant
      S5, P5 in BS8747:2007 UK guide for reinforced bitumen membranes
      BS EN ISO 140 - 18:2006 system tested for sound intensity on metal deck
      EXT.F.AA rating to BS 476 Part 3 External Fire Exposure Roofs
  • Environmental credentials
      Reinforcement used in capping sheet is made from recycled polyester
      Bauder insulation is CFC and HCFC free with zero ODP
      BRE Green Guide Generic A Rating for PIR insulation Element No 1415320205
  • Installation and maintenance
    The quality and experience of the installing operative is paramount to ensuring a successful project. Bauder Approved Contractors are the only people fully trained and certified to install our products. They provide the necessary experience that our exceptional guarantee demands.